Tantec Power Generator HV-X is a new series of advanced corona and plasma power supplies, versatile for stand-alone surface treaters or as a fully integrated treater component in automated lines built by OEM’s.
For stand-alone treaters the HV-X Power Supply series is either controlled by an operator interface control with a 5.7” graphic touch display including a built-in PLC with 16 inputs and 16 outputs and RS485 Modbus port for data management or via a hard wired PLC interface.
For OEM’s the standard RTU 4-Wire Modbus control offers a unique communication platform.
Profibus, CANopen and others are optional and require a separate protocol converter to provide instant bus connectivity, i.e. Anybus Communicator.
Generator HV-X02, HV-X10 and HV-X20
HV-X power generators are available with 200, 1000 and 2000 Watt power output, and operate with 17 different high voltage transformers in configurations ranging from 2 kV up to 80 kV output voltage.
This extensive span provides surface treatment solutions for all products regardless of part size, shape or capacity.
Technical specifications
Control modes: | |
Simple mode: | Only the very basic parameters can be adjusted using the knob and the LCD display on the front panel. |
Modbus (Standard): | Full parameter controlling incl. setting, storing, verification and surveillance of all parameters. (Profibus, CANopen and other bus controls are optional). |
Operator interface control, Tantec Remote-X. (Optional): | Full parameter controlling incl. setting, storing, verification and surveillance of all parameters. |
PLC configuration (Standard): | Via main machine PLC or similar central control the most important parameters can be controlled and adjusted. |
Other features: | |
Output discharge control: | Either voltage or power limitation. |
Watt density control: | Based on parts/min., m/min. or m2/min. (Bus/Operator Interface Control mode only). |
Advanced treatment: | Timer with 5 modes, 0.02-60 seconds. |
Electrode matching: | 70, 80, 90 and 100%. |
Technical Specifications | HV-X02 | HV-X10 | HV-X20 | HT-Transformers |
Mains voltage and frequency | 100-240 VAC 50/60 Hz | 100-240 VAC 50/50 Hz | 100-240 VAC 50/50 Hz | 400 V |
Output voltage/power | Max. 400 V/0-200 Watt | Max. 400 Vp/0-1000 Watt | Max. 400 Vp/0-2000 Watt (110 V: Max. 1500 Watt) | 1–40 kV (17 types)/0-2000 Watt |
Power consumption | 300 VA | 1200 VA | 2150 VA | 0-2000 Watt |
Ramp up time | 5-30 ms, depending on power load | 5-30 ms, depending on power load | 5-30 ms, depending on power load | 5-30 ms, depending on power load |
Shut down time | 1 ms | 1 ms | 1 ms | 1 ms |
Dimensions in mm (LxWxH) | 430 x 470 x 200 | 430 x 470 x 200 | 430 x 470 x 200 | 210 x 164 x 218 (Dry) | 242 x 242 x 267 (Oil) |
Weight in kg | 12.5 | 12.5 | 14.5 | 5-11 kg, depending on type of transformer |
Operator Interface Control | 5.7” STN color touch display | 5.7” STN color touch display | 5.7” STN color touch display | |
(Optional) | Ports: (1) USB – (1) Ethernet – (1) Serial RS485 | Ports: (1) USB – (1) Ethernet – (1) Serial RS485 | Ports: (1) USB – (1) Ethernet – (1) Serial RS485 | N/A |
Bus communication system | Standard: RTU 4-Wire Modbus, 57.6Kbaud, 8bit. Optional: CANopen/Profibus and others | Standard: RTU 4-Wire Modbus,57.6Kbaud, 8bit. Optional: CANopen/Profibus and others | Standard: RTU 4-Wire Modbus,57.6Kbaud, 8bit. Optional: CANopen/Profibus and others | N/A |
Regulation compliance | CE – RoHs – WEEE | CE – RoHs – WEEE | CE – RoHs – WEEE | CE – RoHs – WEEE |